top of page
Search

Reducing Labor, Utilities, and Contamination Risk with Sterile Antifoam Solutions

  • Writer: Scalebridge Biolabs
    Scalebridge Biolabs
  • 6 days ago
  • 4 min read

Cut autoclave prep time to zero while improving sterility and consistency in every batch.


Every bioprocess engineer knows the routine.A few hours before inoculation, someone needs to prepare antifoam bottles, label them, run them through the autoclave, and make sure everything cools down in time for use.


It sounds simple—but between prep time, steam load, QC release, and the occasional autoclave delay, this small task quietly drains hours of labor and hundreds of dollars per batch.


At Scalebridge Biolabs, we developed Naturafoam, a ready-to-use sterile antifoam designed to remove that inefficiency once and for all.



The Real Cost of “Simple” Antifoam Preparation


In most cultivated-meat facilities, antifoam is delivered as a non-sterile liquid that must be portioned and sterilized on-site.


A typical prep workflow looks like this:

  1. Prep (tubing, filter, etc.), fill and label bottles (1–2 h)

  2. Autoclave load, run, cool, and unload (2–6 h)

  3. (optional) QC release (0.5–1 h)

  4. Connect aseptically to the bioreactor feed line


When multiplied across multiple bioreactors or campaigns, this routine consumes dozens of technician hours every month and occupies valuable autoclave capacity that could be used for critical media or buffer prep.


💡 Engineering Note:


Oil-based antifoams are notoriously difficult to sterilize uniformly. For container volumes above 2 L, heat penetration becomes inconsistent because of the low thermal conductivity and slow convection in oil.


Unless a brute-force autoclave cycle exceeding 5 hours is used, the internal temperature may never reach sterilizing levels—posing both sterility risk and quality variation.


This is one of the key reasons why many facilities now prefer ready-to-use sterile formulations.


A Technoeconomic Comparison: Non-Sterile vs. Naturafoam

Step

Non-Sterile Antifoam

Naturafoam (Sterile)

Savings

Labor (prep, autoclave load/unload, QC)

2–3 h

0 h

↓ $100–$150

Utilities (steam, cooling, water)

Moderate

0

↓ $15–$30

Equipment use (autoclave, space)

Occupied

Free

↓ hidden

Contamination risk

Moderate to high

Minimal

↓ batch-loss risk


When Scale Breaks the Math: Why Antifoam Sterilization Doesn’t Scale Linearly


The technoeconomic comparison above might make it look like antifoam prep is a small cost driver — but that’s only true at small or pilot scale.


Once you move from 200 L to 2,000 L or 20,000 L production reactors, the picture changes completely.The limiting factor isn’t just labor or utilities — it’s physics and autoclave throughput.


Oil-based antifoam has poor heat conduction and limited convection, so containers above ~2 L heat unevenly. Unless you run brute-force autoclave cycles exceeding 5 hours, you can’t reliably achieve uniform sterilization throughout the volume. For that reason, most facilities cap oil antifoam prep at 2 L bottles.


Now imagine scaling that up - all the way up to a plant whose capacity is 5x 20,000L!

Reactor / Plant

30-Day Antifoam Need

2 L Bottles

Autoclave Cycles*

Autoclave Occupancy

Operator Hours†

Labor $

Utilities $

Total (Labor+Utilities)

200 L

0.3–1.2 L

1

1

4 h

0.75 h

$37.5

$25

$62.5

2,000 L

3–12 L

2–6

1

4 h

1.00–2.00 h

$50–$100

$25

$75–$125

20,000 L

30–120 L

15–60

2–6

8–24 h

4.75–18.00 h

$237.5–$900

$50–$150

$287.5–$1,050

100,000 L (5×20 kL)

150–600 L

75–300

8–30

32–120 h

22.75–90.00 h

$1,137.5–$4,500

$200–$750

$1,337.5–$5,250

* 10 bottles per cycle; rounded up to whole cycles

† Operator time = 15 min/bottle + 30 min/cycle (load/unload)


💡 What this means in practice


For a 100,000 L plant (5x 20,000L reactors), preparing just one month’s supply of oil-based antifoam at the higher end of typical dosing can require

  • ~300 two-liter bottles,

  • about 30 autoclave cycles,

  • roughly 120 hours of autoclave occupancy (≈ 5 days),

  • and up to 90 hours of operator time for bottle prep, labeling, and load/unload.


ree

Even at 20 kL scale, that still means 5–18 hours of technician labor and 8–24 hours of autoclave use each month. What looks like a small cost item in a technoeconomic table quickly becomes an operational constraint.


Naturafoam removes this hidden bottleneck entirely: it’s pre-sterilized, ready to connect, and scales from 200 L to 100,000 L processes with the same one-step workflow—no bottles, no autoclave, no prep time.


In Conclusion


At pilot scale, autoclaving a few bottles of antifoam may seem manageable. But as facilities scale to 20 kL, 100 kL, and beyond, that same routine quickly becomes a logistical bottleneck — consuming autoclave time, technician hours, and valuable production windows.


Naturafoam was designed to scale with your process. It’s available in 1 L to 200 L sterile formats — so a single 200 L Naturafoam bag can easily support a 20,000 L continuous process for an entire 30-day campaign. No more bottle prep. No more autoclave cycles. Just a ready-to-connect, food-grade sterile solution that fits directly into large-scale bioprocess operations.


For facilities looking for deeper integration, Scalebridge Biolabs can support on-site implementation — including bulk preparation, sterile filtration, and facility-specific connection formats — ensuring seamless adoption without changes to your validated systems.


Ready to Simplify Foam Control?


If your team still prepares antifoam bottles before every run, there’s a better way. Naturafoam arrives sterile, food-grade, and ready to connect — no autoclave, no prep, no downtime.


Request a sample or quote today at www.scalebridgebio.com/contact



 
 
 

Comments